solas requirements for spare fire extinguishers

The door must not be capable of being held back. 0000006691 00000 n 1 For fire extinguishers of the same type, capable of being recharged on board, the spare charges should be provided as follows: 100% for the first 10 extinguishers and 50% for the remaining extinguishers but not more than 60 (fractions to be rounded off to next number). An application form shall be sent o the STA for approval. What is the requirement for spare charges of fire extinguishers? Vessel operators have been advised in the past that SOLAS requirements for foam . Squeeze the operating lever to discharge the fire extinguishing agent. 3.6.13.2 Regulations 10.10.2.1 and 10.10.2.2 do not apply in respect of a vessel that is not a Safety Convention vessel, is of less than 500 gross tonnage and, if the vessel is not a cargo vessel, is engaged on a sheltered waters voyage or a near coastal voyage, Class 2. The words "This extinguisher meets all requirements of 49 CFR 173.306" may be displayed on fire extinguishers manufactured prior to January 1, 1976; ( 5 ) Each non-specification fire extinguisher must be packaged as an inner packaging within a combination outer packaging. endobj 20L Polyethylene bottle. Every fire hose must have the same diameter, but hoses in machinery spaces and other interior locations may have a smaller diameter than hoses in other locations if the smaller diameter is for the purpose of convenient handling. All pressure switch interlocks should be reset and returned to service. 0000004444 00000 n References: (a) SOLAS, International Convention for the Safety of Life at Sea, Consolidated Edition 2014, as amended (b) FSS Code, International Code for Fire Safety Systems 2015 Edition, as amended (c) IMO Circular . 3 0 obj 3.6.12.1 For the purpose of regulation 10.7.1.2, the expression "it is shown to the satisfaction of the Administration that a passenger ship is engaged on voyages of such short duration that it would be unreasonable to apply the requirements of paragraph 7.1.1" is to be read as "a passenger ship is engaged on voyages of not more than 48hours' duration during which the cargo holds are opened to discharge or receive cargo.". Capesize with CCS had approximately 43% less on Detention Rate than the global average. <>/XObject<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 595.32 841.92] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>> 3.4.3.1 Regulation 7.8.1 applies in respect of a vessel that is not a Safety Convention vessel only if it: 3.4.3.2 The fire patrols required by regulation 7.8.1 must be performed at least once every hour and include a patrol of the entire vessel. 3.5.1.1 The class divisions requirements of regulation 9.2.3.4 for stairways and lift trunks that penetrate more than a single deck apply to any area, such as a landing or corridor, between the stairways or lift trunks, if feasible. The emergency fire pump must be provided with its independent suction arrangement and the total suction head should not exceed 4.5 meters under all conditions of list or trim The emergency fire pump capacity to be at least 25m3/hr delivering two inches bore jet of water having a horizontal throw not less than 40 ft Marine Gyaan Encyclopedia is a free online resource aims to document all maritime subjects and queries to replace bulky reference books. If this is impracticable, or for other purposes, and specie rooms and storerooms. 0000063129 00000 n Fire Protection & Security System is crucial & Non-compromising to Human Lives, Valuables, Properties, Continuity of Business & other Economic Activities / Resources. Not less than two such applicators shall be available in the ship for use in any such space. 0000001466 00000 n <> An international load line certificate shall be issued to ships that have been surveyed and marked in accordance with the Convention on Load Lines and that comply with these regulations. How does Lloyd's Register help? 0000001000 00000 n Except as provided in iii, the gap at the bottom of the door should be the minimum needed to open and close the door and in no case more than 12 mm. One portable water fire extinguisher of at least 9 L capacity or one portable fire extinguisher of equivalent fire-extinguishing capability must be provided next to the access to each store-room for each 232 m, Each galley and each pantry that contains cooking facilities must be provided with one portable dry-chemical fire extinguisher of at least 4.5 kg capacity or one portable fire extinguisher of equivalent fire-extinguishing capability for each 232 m. Each control station must be provided with one portable fire extinguisher of a type described in paragraph (b). hbbd```b``@$L,0QZ`v+d"^I'&EvUJHh * a3b+'C8uPDg b A power-driven fire pump must be self-priming and fitted with pressure gauges on their suction and discharge sides. C L DUBEY EXERCISE 11 (Grain Stability), C L DUBEY EXERCISE 02 : Simpsons Rule. Not more than 60 total spare charges are required. 3.1.2.1 For the purposes of regulation 4.2.2.4, the air pipes on any oil tank or part of the oil fuel system must be flame-screened and terminate on an open deck, if feasible. 3.8.2.6 On a cargo vessel of 500 gross tonnage or more, if one of the means of escape required by regulation 13.3.3.2 or 13.3.3.3 from a restricted space or group of spaces connects more than two decks, one of those means must be a readily accessible stairway enclosure that provides continuous fire shelter from the space or group of spaces to the closest lifeboat and life-raft embarkation deck or muster station, if feasible. xM8H:0v,F?evi=L,[ q+~UvFY Only refills approved for the extinguisher may be used for recharging. 3.12.2.3 In the case of a vessel that is not a Safety Convention vessel and that is engaged on a sheltered waters voyage or a near coastal voyage, Class 2, the reference in regulation 20.6.2.2.1 to the word "three" is to be read as a reference to the word "one". M.Ventura SOLAS - Fire Protection 30 Portable Fire Extinguishers Ships with GRT > 1,000 shall have at least 5 portable fire extinguishers distributed in the accommodation area, service areas and control stations One of the portable fire extinguishers intended for use in any space shall be stowed near the entrance to that space. 3.11.1.1 The "NO SMOKING" signs required by regulation 18.7.10 must be in English and French as well as in the working language of the vessel. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); google_ad_client = "ca-pub-7136153532409610"; It is recommended that the remaining portable fire extinguishers in the public spaces and workshops be located at or near the main entrances and exits. Dit onderwerp bevat de volgende rubrieken. Interested parties also are referred to the applicable regulations, and NVIC 06-05, Unified Interpretations of SOLAS . should be inspected to ensure they have not been obstructed by the storage of spare parts Actuation of the fixed fireextinguishing system for the propulsion machinery space. You may experience longer than usual wait times or partial service interruptions. 3.6.8.6 Regulation 10.3.3 does not apply in respect of a vessel that is not a Safety Convention vessel and is engaged on a sheltered waters voyage or a near coastal voyage, Class 2. 1910.157 (c) (2) Only approved portable fire extinguishers shall be used to meet the requirements of this section. On-board Training, Drills and Inspections of Fire Appliances & Life-Saving Appliances Requirement SOLAS Regulations Service company trailer Blog you for requirements for some or station. 3.6.13.3 Regulation 10.10.2.3 applies only in respect of tankers of 500 gross tonnage or more. Interested in flying the Dutch flag? Is screwed or riveted to either of the vertical edges of the door panel. In the case where that the additional portable fire extinguishers provided onboard in accordance with above (1), the information should be written in fire control plans onboard. Cold resistance. "^XPx#mW]ZuKf[M(KJT{m4RKSg..]yY3QE|XX=8,7YaM&qE. (See also Regulation 13). stream Except as provided in iii, the gap at the bottom of the door should be the minimum needed to open and close the door and in no case more than 12 mm, be reasonably gastight if the door is fitted between a machinery space and an accommodation space, and. a) The area within the outside boundary of each accommodation space below the bulkhead deck must be provided with the greater of: i. two portable water fire extinguishers of at least 9 L capacity each or two portable fire extinguishers of equivalent fire-extinguishing capability, and, ii. xref Copyright Marinegyaan 2020. 1 A breathing apparatus required by Chapter II-2 of SOLAS must be approved by the Manager, Ship Inspection and Registration, or a survey authority and must, in addition to meeting the requirement of the Fire Safety Systems Code, be a self-contained breathing apparatus complying with 2, 3 and 4. One outside or near each radio room exit. the ships fire control plans to be approved, and re-approved following an amendment, by the RO on behalf of the NSI; Alternatively, the details, as set out in SOLAS regulation II-2/15.2.4.1, may be set out in a booklet, a copy of which shall be supplied to each officer, and one copy shall at all times be available on board in an accessible position. For fire extinguishers which can not be recharged onboard, additional portable fire extinguishers of the same quantity, type, capacity and number as determined in above 1 shall be provided. 0000002531 00000 n <> Manual fire dampers must be operable from both sides of the deck or bulkhead. 3.5.6.1 Despite regulation 9.7.3.1, ventilation ducts with a free cross-sectional area equal to, or less than, 0.02 m2 that pass through "A" class bulkheads or decks must, instead of meeting the requirements of that regulation that apply to those ducts, meet the requirements of that regulation that apply to ducts with a free cross-sectional area exceeding 0.02 m2 but not exceeding 0.075 m2. 0000005926 00000 n Bij klikken wordt een externe website met een relatieoverzicht geopend op overheid.nl. 0000003654 00000 n 3.6.14.1 In addition to the requirements of regulation 10, a passenger vessel on a near coastal voyage, Class 1 or an unlimited voyage must be provided with the greater of: 3.6.14.2 In addition to the requirements of regulation 10, a passenger vessel on a sheltered waters voyage or a near coastal voyage, Class 2 must be provided with: 3.6.14.3 In addition to the requirements of regulation 10, a cargo vessel must be provided with: 3.7.1.1 The public address system or other means of communication required by regulation 12.3 must be available on all vessels throughout the spaces referred to in that regulation, the muster stations, the embarkation stations and the machinery spaces. 200L Drum. Instructions for recharging should be carried onboard. 2352 0 obj <>stream hb```f`` ,@Q,-/ Z ;RPYw6$8103y@@1a n`z,bln !FVJ *W 3.6.10.1 Regulations 10.5.1.2.1,10.5.2.2.1 and 10.5.3.2.1 do not apply in respect of a vessel that is not a Safety Convention vessel, is of less than 500 gross tonnage and is engaged on a sheltered waters voyage or a near coastal voyage, Class 2. According to SOLAS requirements the minimum number of fireman's outfit required on board are as follows: 1) For vessels between 500-2500 tons minimum two sets are required. 3.2.2.2 If organic foam is used in a cargo space or a refrigerated compartment of a service space: 3.2.3.1 In addition to the requirements of regulation 5, the trunks and ducts of ventilation systems must be constructed of non-combustible materials. Manual alarm systems normally present inside bulb thermometer: pumps will either day or spare fire main system is carried out more pipes shall be opened from cargo. Servicing of the cylinders must be performed to the satisfaction of the lassification ociety surveyor. Every door in an "A" class division must: overlap the door frame at the top and sides and allow for a gap, between the edges of the door and the door frame, that is the minimum needed to open and close the door. Despite paragraph (b), if the vessel is of 500 gross tonnage or less and is engaged on a sheltered waters voyage or a near coastal voyage, Class 2, each main vertical zone on or above the bulkhead deck must be provided with one portable fire extinguisher of a type described in subparagraph (a)(i). All fire extinguishers together with propellant cartridges to be hydraulically tested in accordance with the recognized standard or the manufacturer's instruction Res. Water streams may be used for cooling adjacent areas or as a fine spray to reduce flame radiant heat. 0000000736 00000 n Transport Canada is closely monitoring the COVID-19 situation. Our encyclopedia covers a great collection of study materials and detailed notes in subjects such as Navigation, Cargo work, Ship operation technology, Meteorology, ROR and Ship Stability etc. 0000002278 00000 n two portable fire extinguishers of a type described in subparagraph (i) for each 15 m, or fraction of 15 m, in length of the zone. cylinders, the required spare capacity may be reduced by one third. 2.4 Unless expressly provided by the Unified interpretations of SOLAS chapter II-2, the FSS Code, the FTP Code and related fire test procedures (MSC/Circ.1120) or SOLAS regulation II-2/10.5, the following table should be applied to the number and arrangement of portable fire extinguishers in machinery spaces of category A. 2 A self contained breathing apparatus must: 0000006151 00000 n Holds the fire extinguisher securely in place but provides quick and positive release of the fire extinguisher for immediate use. The number of spare charges required by regulation 6.2 for portable extinguishers should be in accordance with the provisions of MSC Circular 847, namely: Save my name, email, and website in this browser for the next time I comment. 1 0 obj FIR-001 5 of 24 10/21 endobj be fitted with a steel sleeve at least 1 mm thick and at least 900 mm long divided equally on each side of the bulkhead, ceiling or lining. 3.6.3.2 In addition to the isolating valves required by regulation 10.2.1.4.1, valves must be fitted to sections of the fire main that: 3.6.3.3 The valves required by paragraph 3.6.3.2 must be: 3.6.3.4 Every valve fitted to fire piping must be designed to open with a counter-clockwise rotation of the valve's handle. Standard for Portable Fire Extinguishers. Is carrying more than 25 berthed passengers or more than 50 passengers, or. Your email address will not be published. 3.11.2.1 The operations manual required by regulation 18.8.1 must be in the working language of the vessel. 3 0 obj requirements of SOLAS except where these recommendations or requirements are superseded by this Notice. 0000002179 00000 n 0000005727 00000 n A manual fire pump must be operable without the need for manual priming and must be capable of delivering a jet of water of at least 12 m, A fire pump's sea connection must have arrangements to prevent blockage of the connection's inlet by ice and slush, and. Most common boundaries of pipe type in crew in releasing station for solas and is not confined spaces and hydrants. not more than 20 spare charges in total, equally distributed over the available types, are required. Min capacity of foam is 9l. >Accommodation, service space and control station shall be provided with portable fire extinguishers of appropriate type and sufficient numbers >Co2 fire extinguishers are not used in accommodation X . This is especially important to note when the fire pumps are being utilized to also supply the foam system. The requirements for approval of such extinguishers shall be governed by para.6 of the DGS Order 6 of 2013. In the case of organic foam used in a refrigerated service space on a vessel of aluminum construction, the boundaries to the space must be of steel or aluminum construction. b) The area within the outside boundary of each accommodation space on or above the bulkhead deck must be provided with one portable fire extinguisher of a type described in subparagraph (a)(i) for each 15 m, or fraction of 15 m, in length of the area. If you cannot get through, please contact us by email. 3.2.4.1 The requirements of regulation 5.3.2.4 apply to plastic piping in accommodation and service spaces and control stations and must be approved by the Minister as meeting the flame-spread requirements set out in Annex 1 to the FTP Code. 3.8.2.4 The means of escape required by regulation 13.3.3.1 must be separated so as to minimize the possibility of their being blocked at the same time as a result of an incident. Accommodation spaces, service spaces and control stations to be provided with PFE. In our position such fire for attracting attention and checked. b. In response, we have issued some transportation-related measures and guidance. 0000005077 00000 n ]aUs +J_lTT!cT,ry[586jCef+b4X40745;7-^=P.eHJa9&\A][FvK$NMteN4bIROq HVRH}WGLK743&q3$2@g>xvw!1LYnmvs.x,$` ktaQSERx. 2 0 obj At a minimum, inspection needs to consist of the following steps: Make sure it is located in its designated place Make sure the extinguisher is visible or that there is signage indicating where the extinguisher is located Make sure you can easily access the extinguisher Ensure the pressure gauge is in the operable range or position 3.6.10.2 The requirement in regulation 10.5.2.2.2 with respect to foam fire extinguishers of at least 45 L capacity each or equivalent does not apply in respect of a vessel that is not a Safety Convention vessel, is of less than 500 gross tonnage and is engaged on a sheltered waters voyage or a near coastal voyage, Class 2. be fitted with a steel sleeve at least 1 mm thick and at least 200 mm long divided equally on each side of the bulkhead, ceiling or lining. Must be made of corrosion-resistant metal or galvanized steel, and. Indian tribes, involve equipment approval and carriage requirements, a person with demonstrable competence. {3$pKjnl8X}l6e'|t2Q(5L{$ZF/#* Make sure that extinguishers are clearly visible, and any location signs are clear. These spare bottles are to be in addition to the spare bottles required for fireman's outfit. Each main vertical zone below the bulkhead deck must be provided with the greater of: two portable water fire extinguishers of at least 9 L capacity each or two portable fire extinguishers of equivalent fire-extinguishing capability, and. If the stairway enclosure is not feasible, details must be provided which demonstrate the route by which the crew can escape from any deck to the embarkation station without entering any space where the fire may be located, the details must clearly show that the route is protected from the fire by A class bulkheads for its whole length. 3.1.3.1 The mechanical ventilation system required by regulation 4.5.4.1 must: 3.2.1.1 In addition to the requirements of regulation 5.2, a vessel must be fitted with means to automatically shut down the ventilation fans for a space when a fixed fire-extinguishing system for that space is activated. PART IV: SOLAS CHAPTER II-2 Construction Fire protection, fire detection and fire extinction, PART II: SOLAS CHAPTER I GENERAL PROVISIONS, PART III: SOLAS CHAPTER II-1 CONSTRUCTION STRUCTURE, SUBDIVISION AND STABILITY, MACHINERY AND ELECTRICAL INSTALLATIONS, PART IV: SOLAS CHAPTER II-2 CONSTRUCTION FIRE PROTECTION, FIRE DETECTION AND FIRE EXTINCTION, PART V: SOLAS CHAPTER III LIFE-SAVING APPLIANCES AND ARRANGEMENTS, PART VI: SOLAS CHAPTER XII ADDITIONAL SAFETY MEASURES FOR BULK CARRIERS, TP 14612: Procedures for Approval of Life-Saving Appliances and Fire Safety Systems, Equipment and Products, Transportation of Dangerous Goods Regulations, transportation-related measures and guidance, The Minister's approval is not required when section 6 of the FTP Code applies, and. 7.1.3 The extinguisher should be manufactured to a recognized national or international standard for marine use. 0000002849 00000 n If one of those pumps is manually operated and is located outside the space where the other fire pump required by that regulation and its source of power are located, the manually operated fire pump may also be used for the emergency fire pump if one is required by regulation 10.2.2.3.1.2. to be included in the maintenance plan on board the ship, as referred to in SOLAS regulation II-2/14.2.2. General discussion regarding the solas requirements for spare fire extinguishers checked for local protection. hb```"CVeah`P 9=rXPdhBs~Il` @xt I& 0Q(. \ m``6h covered with a steel-sheet protective facing. 1. 69% Seafarers Suffering Extreme Financial Crisis, Says Maritime Charity Survey. bDN?>_^K?> Schedule 2 Fire extinguishers (section 11) 1 In this clause: extinguisher means a fire extinguisher other than a portable fire extinguisher. 0000000907 00000 n 3.12.2.1 If a water curtain is part of fixed fire-extinguishing system referred to in regulation 20.6.1, a strip 900 mm wide must be painted on the deck under the water curtain and marked "TO BE KEPT CLEAR OF VEHICLES AT ALL TIMES / LAISSER CET ESPACE LIBRE EN TOUT TEMPS". Code provides an adequate suction or sprinkler nozzle. 3.6.6.1 In addition to the requirements of regulation 10.2.2, the following requirements must be met in respect of a vessel's fire pumps: 3.6.6.2 If a bilge pump is to be used as a fire pump as permitted by regulation 10.2.2.1, the bilge pumping system and the fire pumping system must be capable of simultaneous operation. <>/Metadata 1750 0 R/ViewerPreferences 1751 0 R>> 0000064064 00000 n Petroleum and water-soluble liquid fire (dual purposes) SSNMF. Fluorinated protein foam extinguishing concentrate "Mighty Foam". The design of the piping system must be taken into consideration in determining the number of fire hoses, The minimum diameter of a fire hose must be 38 mm, and. The pump and its controls shall be installed outside the space or spaces to be protected. Spanner wrenches ensures at ship for extinguishers which a chain reaction involving certain restrictions regarding fixed. Certification A notice in English and French indicating the connection's location and the maximum working pressure of the piping system must be posted on the vessel. An application to use such alterative loadingcondition should be submitted to STA for acceptance well within time of seatrials, estos precios no incluyen los gastos de envo de los Productos. overlap the door frame at the top and sides and allow for a gap, between the edges of the door and the top, bottom and sides of the door frame, that is the minimum needed to open and close the door. Readily recharged by the vessel's personnel one spare unit of the same classification. 2315 0 obj <> endobj Fire Control Planand verified during the review. endobj 51 22 Not more than 60 total spare charges are required. 1981 revision A.951(23)) X X X . endobj when fitted on a stairway enclosure, a main vertical zone or an escape route, have a gap at the bottom that is the minimum needed to open and close the door, in order to reasonably prevent the ingress of smoke. 0000001312 00000 n 3.5.5.1 An automatic fire damper required by regulation 9.7.2.1 to be fitted in a galley ventilation duct must be of a fail-safe design and be capable of being manually operated from both sides of the division through which the duct passes. . Fire Fighting & Protection; Safety & Protection; Fire & Gas Detection; SYSTEMS . 4 Spare Charges, Additional Fire Extinguishers and Refilling of Extinguishers a. Wheeled (mobile) fire extinguishers, Verify all extinguishers are in place, properly arranged, and are in proper condition. %PDF-1.4 % SOLAS Chap.II/2-FFA REQUIREMENTS exceeds 10% of the original charge as stamped on the bottle or cartridge. All EEBD training units are to be clearly marked. If this isimpracticable, perhaps enough to ignite its paint. %PDF-1.5 If a steel sleeve is fitted, the gap between the sleeve and the duct must be fully packed with a non-combustible material and the sleeve's ends must be sealed with a fire-retardant flexible sealant. 2 0 obj Every pressure container for a fixed fire-extinguishing system must bear a mark indicating that it: 3.6.2.1 The pipes, valves and fittings used with the equipment required by regulation 10.2: 3.6.3.1 If the fire main is an integral part of a fixed deck foam fire-extinguishing system with monitors, the isolating valves required by regulation 10.2.1.4.1 must be fitted immediately forward of each monitor. Solas Regulations Of Portable Fire Extinguishers >Portable fire extinguishers should be ready to use and easily visible with recommended color cording. Any other vessel of less than 500 gross tonnage must be provided with one hydrant in each machinery space of category A. Chapter 12: Rising & Setting Of Celestial Bodies, EXERCISE 29 RISING/SETTING AZIMUTH -SUN, EXERCISE 30 LATITUDE BY MERIDIAN ALTITUDE SUN, EXERCISE 35 LATITUDE BY MERIDIAN ALTITUDE STAR, EXERCISE 37- LONGITUDE BY CHRONOMETER STAR, Previous Years MMD Function wise Questions, Naval Architecture MEO CLASS 4 WRITTEN PAPER, GENERAL ENGINEERING KNOWLEDGE MEO CLASS 4 MMD PAPER, Motor Engineering MEO CLASS 4 MMD PAPER. . At least one should be discharged annually and the retention of contents checked. In English or French, or in both languages, according to the needs of the shore-side fire-fighting personnel. is screwed or riveted to either of the vertical edges of the door panel. The revisions and addition read as follows Sec. In the case of organic foam used in a refrigerated cargo space or a refrigerated compartment of a service space on a vessel of steel construction, the boundaries to the space must be of steel construction, and. If you would like to receive updates on all changes (daily e-mail, if any changes)to the regulatory framework, click here followed by clicking on 'Abonneer mij op dit zoekresultaat' (right upper corner). endstream endobj startxref 3.6.11.1 For the purpose of regulation 10.6.3.2, the fire-extinguishing arrangements must include fixed gas fire-extinguishing systems, fixed foam fire-extinguishing systems and fixed pressure water-spraying f ire-extinguishing systems that meet the requirements of the FSS Code for the system. What is wrong with the shipping as a career? The spare fire extinguisher requirements in 46 CFR 34.50-10(a), . google_ad_slot = "8641225286"; Wet air inlets to solas requirements for spare fire extinguishers? Operable from positions that are easily accessible and protected from freezing, fire and explosions, and, A passenger vessel on a near coastal voyage, Class 1 or an unlimited voyage and a vessel of 500 gross tonnage or more must be provided, in each machinery space of category A, with one hydrant on the port side and one hydrant on the starboard side, and. Is fitted with automatic fire dampers that can be operated manually, if the free cross-sectional area of the ducts is more than 0.085 m2. Onderstaande relaties zijn gevonden bij document. A.951(23), para 9.1.2 All 10-yearly Shore Wheeled (mobile) fire extinguishers Verify all extinguishers are in place, properly arranged, and in proper condition MSC.1/Circ.1432, All of the entries have been written and approved by actual scholars, which means you wont have a problem when it comes time to cite sources. 2.1.1.1 All material, equipment and system required approval shall be approved in accordance with TP 14612: Procedures for Approval of Life-Saving Appliances and Fire Safety Systems, Equipment and Products . 4 0 obj 3.6.4.1 Despite regulation 10.2.1.5.1, on a cargo vessel of less than 500 gross tonnage or on a passenger vessel of less than 500 gross tonnage that is not a Safety Convention vessel, the number and position of hydrants must be such that one jet of water can reach any part of the vessel. However, the applicable regulations must be consulted for specific situations, especially if the SOLAS option for structural fire protection is not selected. 3.6.1.2 Paragraph 3.6.1.1 does not apply in respect of the design of pressure containers for a fixed fire-extinguishing system. Request Information. It can protect one deep fat fryer (50 litres, 800mm x 400mm), or up to three deep fat fryers (each 27 litres, 400mm x 360mm). For extinguishing this class of fire, the sleeve needs to extend beyond the length of the pipe, crewmen must maintain a safe distance from the fire unless they are properly protected and equipped for the attack.