If youre not sure which is the best timer for your pool to get, we have a full blogpost for which Intermatic timer you should get for your pool. First, verify the power is turned off at the breaker panel. More. Thanks in advance! "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
}
. Analog timers are the simplest type of pool pump timer and are easy to use (and the cheapest). Clean the gears with a toothbrush if you see debris or gunk in them. Hey there! Once you do some you will want to re-tighten the hold down screw on the timer pin so it stays in place. Step 3 I hope this helps. But my new timer will not work either. Open following links to identify timer and then add a comment. Black goes to _1 Take them off and inspect them and look for twists in them. Could also be grit or insects inside of the gears of the clock motor. The problem lies, where the power dies, as they say, Thanks for the response. Or there could be a bad relay in the control panel, if you have ice cube style relays. Ask Your Own Pool and Spa Question One morning I noticed my pool didnt automatically turn off. Second thing to check is the dial bent or warped, in that area where the on tripper is? Yes, likely a short to ground. #9. The other gears are not and the pump will not turn on or off unless done manually. "logo": {
OPEN TODAY, 12PM TO 3PM. Clock wont move, gear dont move at all. TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. So what you will want to do now is to look for the circuit breaker panel and locate the circuit breaker for your Intermatic Pool Timer and then make sure it is set to the on position. GFCI breakers trip at a very low threshold, doesnt take much. Any idea what may be causing this? My timer runs, then after it reaches the off tripper, it stops, and never goes past the off tripper. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. Trippers are not installed properly Re-install trippers on dial 2. But eventually, like all equipment, intermatic clocks wear out and need to be replaced or repaired. Hi Matthew T104 can only turn one pump on and off. To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. Jun 3, 2013, 10:07 AM You will have ON trippers and OFF trippers, You can place an ON at Noon, and OFF at 1:00 for 1 hours operation, If you manually turned it back on at 3:00, it would stay on until the next OFF tripper (1:00). I can manually turn it on with the lever at the bottom. Manual switch works my aerator. Is it Necessary? Ive seen it happen from lightning strikes, or insect infestation. This site is owned and operated by AJH Trade Group. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. Now remove the terminal cover on the timer. After a power failure the timer clock can start up backwards, mine has done this several times. For any wiring concerns, always refer to the wiring diagram printed on the inside of the timer door. Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. JACUSTOMER-hlvgjzll- : I have just sprayed WD-40 on the switch coils that move the lever that the trippers hit. It sounds like the Line and Load wires are reversed. everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. Why it always stop around 10pm by itself and not moving again? Hi Casey, perhaps the cord or wires are broken? Take a good look at the position of the pins and write down the locations. On mine, the gears behind the dial look metal, but the motor (behind the plate) they look plastic (maybe?) But the next morning it wont engage by itself again, it seems it sticks when getting to the point its supposed to flip on. You can turn the dial and then only wait a few minutes to check is the OFF tab is working. About 1-2 years ago I swapped out this unit because it was sticking and not engaging when it was supposed to. Perhaps you had a power outage during the night? Go for it, a little maintenance expense. "caption": "In The Swim Blog"
You most likely just need to now set the pins and the clock and your timer will work. I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse. Is the timer repairable, or should I just install a new one? Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. Having no power to your pool timer is a common problem and will occur because of three reasons: The first and easiest thing to check is the circuit breaker. I also dont see any ants or other insects. Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts Replacement for T100 Series and Intermatic Time Clocks T101, T102, T103, T104, Pool Timer On Off Clips(4 ON / 4 Off / 8 Screws) : Amazon.com.au: Home Improvement 240V out of the timeclock (Load/Load terminals) and nothing on the motor terminal board? My intermatic timer is about two years old as well. So out comes the soldering gun and the shrink wraps and that did the trick. No broken or loose wires visible. Or one of the wires may have broken, or lost the protective plastic insulation. This is the first step to confirm if there is power or not. Hello have a question some what related. But first, pull the mechanism from the box by releasing the tab at the top (be sure breaker is turned off, first), and inspect the gears and copper tabs on the back, to look for something clogging up the works, insects, lizards, sand, etc. Hi Phil, usually the OFF dog may not be fully pushed onto the dial, or if you examine it closely, it might be worn. Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 This will disengage the dial from the . "@type": "Organization",
my pool cleaner timer dog is set between 8 am and 11 am, everything is working fine manually, except that the pool cleaning pump will not start by the timer dog setting the clock is set correctly and moving . Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side. With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
How do you know if your pool timer is bad? My Polaris booster pump ONLY turns on via the trippers. Flip it from where it is now, to the opposite side. The mechanism for the off tripper doesn't work at all when manually depressed. It started lagging again a week or so ago. BUILT BY HAND IN QUEENS, NYC. "@context": "https://schema.org/",
Theres an issue with the wiring between the circuit breaker and the timer. Is it possible to do this by loosening the timer screw a bit? If there is power going to the timer and the timer appears to be working but the pump isnt turning on and off, then youll need to check the pump. Close. Should You Get a Pool Pump Timer? Is there a separate switch somewhere between breaker and timer? Assuming the wiring is all correct. Reference Manual & Buyer's Guide Another Brick in the Your timer is on a 24-hour cycle. Thank you. I dont see timer gears rotating on any power going to the pump or salt system. You will want to make sure the manual switch under the timer wheel is pushed to the on position. If not, that sounds like a weak/bad motor. Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. Hi Sandra, does the on/off tab switch crisply, or softly? To set it, you just move the on/off "trippers" where you want them. If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. Does the tripper work on other areas of the clock, like near the off tripper? Above you said to connect white to A. and Black to 1what do I do with red? Pools are not cheap! "name": "In The Swim",
Give it a little squirt of WD-40 or similar lubricant. 4 Beds. I not sure if this is the best timer to use. But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. Is that a faulty motor? Perhaps bad wiring or a bad breaker is to blame. The T104RD89 timer will work with a swimming pool motor as long as the motor is 240 VAC and is under 5 HP which is what this timer is rated for. Below is a breakdown of how to wire different Intermatic timer models. Hello, newer pool guy here. The timer appears to be working fine (keeps time). My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. Hello. Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. Because a pool timer is an electrical timer with mechanical aspects, the clock dial portion of the timer pulls out to set the time. Sometimes its way quick just to replace it rather than spend hours troubleshooting. To use an analog timer, you simply need to set when you want the timer to be on and off using trippers. I have a 2 speed pump. AJH Trade Group is a participant in the Amazon Services LLC Associates Program. White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. Would I suspect this is a defective motor? My pump has a plug. I used to run the pump for 8-9 hrs a day. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. With this model can I control both of these motors with two different on and off times. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? It was always fine before. It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. When the power goes out, the timer stops. Date Listed: 18/02/2023; . Hi, I got the same problem as my clock not working. PF1202T Freeze Protection Control Parts - INYOPools.com Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Free Shipping on all Orders over $49! 2nd black goes to -2 Hi Mike, yes I sent you an email to your yahoo acct. Deep down, I figured it was something I did wrong and it was. Thanks for any help you can give. Any suggestions? First you want to make sure there is actually power getting from the power board to the timer itself. Pool co says T104 timer needs replacement and filter cartridge. This morning the customer said it wasn't turning off. 1100 Juanita St , Austin, TX 78704-5351 is a single-family home listed for-sale at $2,649,000. In this case its likely the On/Off trippers, loose wiring, the clock face not being located correctly or a faulty pump. You should always be able to switch your pump on and off manually at the timer. I have a T104. If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. It may or may not reduce the noise level however. The works fine and keeps time while it is on but the second it turns the filter off, it stops keeping time and the cogs stop moving. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. Take them off and inspect them. Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4. Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. At some time the timer was disconnected and the pump wired direct to the breakers. when the lever is in the off position the gears stop turningis this unit wired incorrectly, Natural goes to A After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. Its hard to give a fixed order for the steps you should take as it depends on what you found in the previous steps. Faulty Pump or Wiring from the Timer to the Pump. DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. I have a PF1112T. Reasons Why Pool Timers Stop Working 1. It should loosen up after a few goes when the grease and gunt dissolve. 2,767 Sq. (For outside light timer) The one before was original to the house & I had no trouble. Im sure I hooked it up correctly but when running it gains a little over an hr of time every 24 hours. Now ever sense I did that last week my timer wont shut off or turn on my pool pump. Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. #1. Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. Hi Doug, Check the wiring. Tracing the power it goes from breaker to control panel, and then to the time clock, then to the pump. I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. Pool pump comes on fine with the on dog, but wont turn off. "address": "",
Thanks. LIMITED TO A ONE-TIME RUN OF 666 UNITS. PF1202T Freeze Protection Control Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Save my name, email, and website in this browser for the next time I comment. And Ive noticed lately that the ON is not functioning all the time. There are many reasons why your pool timer may not be working. "height": "219",
Rich. If your pool pump timer is beyond repair, call a professional to replace it. If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . do i need to do something different? If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. Basically youre eliminating possibilities until you find the cause. Paul, it could be that you got a 50hz motor, instead of a 60hz? Other than a couple of weeks, we have spent fifteen years manually turning on our pump. Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. Intermatic timers are a great addition to your pool set up but they can go wrong. Are the gears engaged, in the center, behind the dial? The most common pool timer used for inground pool pumps is the Intermatic time clock. I fastened it very securely. Posted by 4 years ago. All Rights Reserved. You can also apply some of the troubleshooting steps to other brand timers. Hi, new timer out of the box, 200V. Hi Tom, sure you can spray some 3-in-1 or wd-40 on the motor gears, just depress the tab at 12 oclock and pop out the mechanism, to target the oil onto the gears. Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. 3. I have a Model T104P and have a new green on tripper attached. Second thing to check is the dial bent or warped, in that area where the on tripper is? Thank you. Still no luck. Once you figure out what is wrong with the timer, you may be able to do the repair yourself or might have to hire an electrician to come and replace the timer for you. AJH Trade Group Australia Pool Equipment | Pool Lifestyle | Pool Heating | Pool Maintenance | Pool Problems, what to do when the pump circuit breaker continually trips. Please advise. The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. You can replace the entire mechanism or the gears. For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. You will feel the wheel pull out about an 1/8 of an inch and then you will be able to rotate the timer wheel. Or be loose and not making good contact. Hi Chad, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. Motor runs past the on dog but doesnt flip pump on? There is a second switch between the breaker and the timer. Gold OFF tripper works for all models. It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. It also provides a selectable voltage switch that enables you to choose between 120 and 240V, depending on what voltage you use and also has a battery backup option. Hi, then the power for the clock must be from the switch, and not from the breaker? You could spray some light lubricant like WD-40 or 3-in-1 oil onto the gears both for the motor and behind the dial. "keywords": "",
The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. Stupid third question, but does the ON tripper say ON? i have a P1121 intermatic timer connected to a hayward above ground pool pump. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. The timer seems to get stuck prior to reaching the on trippers therfore the pump cant turn on. March 16, 2022 by WildRiverCountry. Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. But if the timer doesnt come back on after a storm, there could be an issue. Terminal A (farthest to the left side) is not connected to anything. Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. The most common pool timer used for inground pool pumps is the Intermatic time clock. You will have live wires exposed and they can kill you if you touch them. Hi. Hi Andy, when a clock is running slow, we might assume power outages, but when it runs fast, we might assume either a 60 hz (US) timeclock hooked up to 50 hz power service (Europe), or vice-versa, or a manufacturing defect in the gear tolerances could cause a synchronous motor timer to run fast.